Finning Caterpillar Gas Engine CHP Ratings

note- THESE ARE INDICATIVE OR PROVISIONAL ONLY – ALWAYS CHECK WITH SUPPLIER FIRST.

 

David Andrews

Technologies Development Manager

Finning Power Systems

688-689 Stirling Road, Slough SL1 4ST, UK

Tel:     +44 (0)1753 497300

www.finning.co.uk

Full EPC and Finance for energy plants (0.5 – 30 MWe):

• Gas Engine and Steam Turbine CHP with District Heating • Energy Centres • Critical Emergency Power Supplies • Landfill Gas Generation • Anaerobic Digestion • Biomass Combustion Heat or Power • Biofuels • Geothermal Power • Geothermal Heat • Geothermal Cooling • PV • Diesel Generation with Raw Vegetable Oil • STOR • Waste to Energy (Pyrolysis, Gasification, Combustion) • Gas to Grid • District Heating • District Cooling • Small Pumped Hydro  • ORC • Civils  • Mechanical  • Electrical to 66kV • ICA •

Gas Fired CHP Summary Sheet
Natural Gas (LHV of 36.2MJ/Nm3)
EngineElectricalHeatElectricalThermalTotalEWJ CircuitExhaust HeatFuelJacketEmissions
DesignationOutputOutputEfficiencyEfficiencyEfficiencyHeat Outputto 120CInput (LHV)TemperatureNOx
kWkW%%%kWkWkWoCmg/Nm3
G3406LE18027132.79%49.36%82.15%17010154999500
CG132-0840042842.28%45.24%87.53%20422494692500
G350848060236.87%46.24%83.10%265337130299500
G3508HT48060432.37%40.73%73.10%3023021483127500
CG132-1260065442.02%45.80%87.82%314340142892500
G351272596235.23%46.74%81.97%407555205899500
G3512HT72589334.52%42.52%77.05%2945992100127500
CG132-1680085642.37%45.34%87.71%406450188892500
G3512E1000107539.81%42.79%82.60%569506251294500
G3512E1200122640.87%41.76%82.63%612614293699500
CG170-121200118943.67%43.27%86.94%608581274893500
G3516975132234.81%47.20%82.01%531791280199500
G3516HT975115835.29%41.91%77.20%3338252763127500
G3516B1100149236.81%49.93%86.75%596896298899500
CG170-161560157643.33%43.78%87.11%772804360093500
G3516C1584180439.04%44.47%83.51%7741030405799500
G3516E1600161341.06%41.39%82.45%823790389794500
G3516H2000190242.64%40.55%83.20%1037865469099500
G3520C2000226839.16%44.41%83.57%10111257510799500
CG170-202000197743.69%43.18%86.87%1005972457893500
G3520E2022218240.78%44.01%84.79%10881094495894500
CG260-123333320644.08%42.40%86.47%14651741756290500
CG260-164300416444.11%42.71%86.82%18602304974990500
Biogas/Landfill Gas (60% CH4)
EngineElectricalHeatElectricalThermalTotalEWJ CircuitExhaust HeatFuelJacketEmissions
DesignationOutputOutputEfficiencyEfficiencyEfficiencyHeat Outputto 150CInputTemperatureNox
kWkW%%%kWkWkWoCmg/Nm3
CG132-0840039442.78%42.14%84.92%20019493588500
G350847066632.02%45.37%77.38%3842821468110500
CG132-1260059542.70%42.35%85.05%301294140588500
G3512770115031.64%47.25%78.88%6325182434110500
CG132-1680079142.76%42.28%85.03%405386187188500
G3516A+1150134336.46%42.58%79.04%4898543154110500
CG170-121200124942.08%43.79%85.87%626623285293500
CG170-161560164141.78%43.95%85.73%823818373493500
G3520C1950200939.55%40.74%80.29%49015194931110500
CG170-202000202142.85%43.30%86.16%1047974466793500
CG260-12
CG260-16
Notes
Fuel consumption tolerance according to ISO 3046/1.  Tolerance is +5% of full load data.
Heat Output tolerance is +- 8% full load data
Heat output is based on Jacket and exhaust heat with exhaust gas temp of 120C except with High Temperature units
Ratings listed above are based in 500mg/Nm3 Nox, ratings based on other emission levels are available on request.